Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging

Abstract: Improved data acquisition and processing strategies for blood oxygenatlon level-dependent (BOlO)-conlrast funcllona1 magnetie resonaneo imaging (fMRI), wllich enhance the functional eontrast-to-nolse ratio (CNR) by sampllng multiple echo limes In a single shot, are descrlbed. The dependence of Ihe CNR on Ti, Ihe image encoding time, and Ihe number of samplod oeho titnes are Investigated for exponentia1 fitting, echo summation, welghled echo summation, and averaglng of corrolalion maps oblainod at different ech… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
358
0
1

Year Published

2000
2000
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 348 publications
(365 citation statements)
references
References 25 publications
6
358
0
1
Order By: Relevance
“…Instead BOLD CVR maps were generated combining the double echo data; the SNR in the BOLD data was increased by weighted summation of the EPI images acquired at each echo time (Posse et al 1999), with the weighting based on a T 2 * map calculated from the average baseline signal at both echo times. This was done for each time point…”
Section: Data Processingmentioning
confidence: 99%
“…Instead BOLD CVR maps were generated combining the double echo data; the SNR in the BOLD data was increased by weighted summation of the EPI images acquired at each echo time (Posse et al 1999), with the weighting based on a T 2 * map calculated from the average baseline signal at both echo times. This was done for each time point…”
Section: Data Processingmentioning
confidence: 99%
“…This is also an advantage for functional imaging studies where very small changes in water signal linewidth must be detected (1,2). However, there is both theoretical (3,4) and experimental (5)(6)(7) evidence that the water resonance in small image voxels in brain is inhomogeneously broadened.…”
Section: Brain Is An Optimal Target For Mri In Part Because the Watermentioning
confidence: 99%
“…Susceptibiltydependent changes in T2* can be accounted for by optimized data analysis on a pixel-by-pixel basis. Parametric mapping has thus shown to be more sensitive than conventional EPI (46). Parametric T2* mapping with multiple spiral readouts after a single excitation has also been demonstrated (47) A similar approach uses the spiral-out, spiral-in technique (48), which combines two measurements with complementary trajectories but identical echo times.…”
Section: Signal Behavior In Bold Fmrimentioning
confidence: 99%
“…The yellow lines show the projection of the direction corresponding to the largest tensor eigenvalue onto the imaging plane. Tensor data were acquired using a turbo STEAM DTI sequence (46,47,130,131) and thresholded according to the intensity in the underlying T1 image. Red, green, and blue colors represent the same direction information (magnitude of left-right, anterior-posterior, and superiorinferior component, respectively), but the color intensity is scaled with the square root of the FA index.…”
Section: Presurgical Mappingmentioning
confidence: 99%